Important:
Turn electricity off at circuit breaker or fuse panel.
Installation Model 1 :: Inside Dryer
- Mount the Con-Cur current sensor in convenient location inside
dryer connection compartment.
- Disconnect and loop neutral (white) dryer power supply wire
through current sensor cutout, then re-connect.
- Connect fan 120v-AC power supply to top (relay) terminals of
Con-Cur Control.

Installation Model 2 :: At Dryer Junction
Box
- Attach electrical junction box to dryer junction box.
- Disconnect and loop neutral (white) dryer power supply wire
through current sensor cutout, then back to dryer junction box
and re-connect.
- Mount Con-Cur current sensor in electrical box. (may require
drilling 2 mounting holes)
- Connect fan 120v-AC power supply to top (relay) terminals of
Con-Cur Control.

Installation Model 3 :: At Breaker
- Mount Con-Cur current sensor in convenient location on fuse/breaker
panel.
- Disconnect and loop neutral (white) dryer power supply wire
through current sensor cutout, then re-connect.
- Connect fan 120v-AC power supply to top (relay) terminals of
Con-Cur Control.

|